I have followed hp docs to setup the connection using direct attached, one hba per server, dual path. Fc san storage reliable, scalable and affordable fc san. Hp msa 2040 12drive bay san dual controller storage. We decided to pull the trigger and purchase an hpe msa 2040 dual controller san.
Common features of hp msa models features msa family host protocols 8 gb fc, 16 gb fc, 1 gbe, 10 gbe, sas. Products sold prior to the november 1, 2015 separation of hewlettpackard company into hewlett packard enterprise company and hp inc. The hp msa 2040 storage array all hp msa storage models offer a common set of features listed in table 1. Hp proliant dl360p gen8 hp msa 2040 dual controller san vmware vsphere. Vm host doesnt see storage hp msa2040 solutions experts. Hpe msa san storage is integrated with todays most widely used hypervisors and operating systems to help you consolidate and reduce costs. Products sold prior to the november 1, 2015 separation of hewlettpackard. The software iscsi adapter handles iscsi processing while communicating with the network adapter. But, contrary to the hp msa 2040, you have to install the software plugin for vmware vaai if you use the p2000 g3. Dec 23, 2014 watch this nugget to learn the basics, iscsi best practices and just how easy it is to get connected.
Connect mac and windows workstations to feature rich high performance storage the hp storage p2000 g3 msa and msa 2040. Hello, im hoping someone can shed some light on this little annoyance. I have an msa2040 with 2 sas controllers, and i have two esx hosts plugged in with a 2 port sas hba, one connection per controller. Msa 2040 sas controller will support up to four 6gb12gb sas connections per controller using minisas hd cables. Hi there just in case anyone else has this trouble. This article outlines the default credentials configured as part of the hp msa storage array and hp storageworks p2000 g3 configuration and their functions. This morning i have been reading once again hpe msa storage configuration and best practices for vmware vsphere and then hpe msa 1040 2040 2042 best practices.
Ive talked to hp directly and they state direct attached thru iscsi is supported with the msa 2040 and vmware. Hp msa 2040 san hdd or ssd for virtual machines hpe. May 07, 2014 attaching a windows 2016 host to a storage center array with fiber channel io cards duration. At the login prompt, enter the default user manage enter the default password. Unfortunately this is our best solution until we aquire an msa 2040. Hi, very useful post i have decided to create in my lab a new vmware environment with 2x hp dl360p gen8 2 cpu with 8 core, 48gb ram, sdhc for esxi 5. Hpe msa storage configuration and best practices for vmware. First of all, many thanks for this accurate and detailed answer. This tutorial is from chris microsoft windows server 2012 704 with r2 updates training. Hp msa 2040 storage configuration and best practices for. I would like to plug my physical vcenter server that has. Apr 02, 2016 in the terminal emulator, connect to controller a. Using the software iscsi adapter, your host can connect to the iscsi storage device through standard network adapters.
Sff disk enclosure msa 2040 supports up to 7 disk enclosures. Carefully reading these documents prepared me to understand what you have just explained and i have to say that make. Hpe msa 2040, a highperformance storage array designed for entrylevel hewlett packard enterprise users desiring 8gb16gb fibre channel fc, 1 gbe10 gbe iscsi, or 12gb sas connectivity. When you configure networking with software iscsi, consider several best practices. Hp ilo how to reset from command line the virtual way. For example, to upgrade to gl225p00202 the msa must already be running gl220xxxx or gl210xxxx. Hpe msa storage configuration and best practices for. Hp msa and hp storageworks p2000 g2 and g3 default admin passwords. Two hp gen9 servers running esxi connected to the msa 2040 san. Preparing a linux computer before cabling to the cli port. Hpe msa 2042 san vmware compatibility guide storagesan. You can bind the software iscsi initiator on the esxi host to a single or multiple vmkernel ports, so that iscsi traffic flows only through the bound ports. Support of direct attach to the msa via iscsi is os dependant.
Getting the serial number for your 3par is one of those regular things you will need support from hpe support team. This update will add several virtualization features into the entrylevel storage msa portfolio. I have now hp msa2040 san connected to two hp proliant servers. The next section msa considerations and best practices for vmware vcenter outlines specific. The solution is based on hp proliant dl380 gen8 servers, hp msa 2040 storage and storefabric sne 16gb host bus adapters.
The next section is msa considerations and best practices for vsphere. Hpe msa 2040 san storage overview hpe support center. Msa storage features and concepts which outlines hpes best practices for configuring the hpe msa storage array. But, contrary to the hp msa 2040, you have to install the. In citrix hcl i found only storage controller msa2040 sas. The hp p2000 g3 and the hp msa 2040 are two widely used entrylevel storage arrays. Find hpe msa 2040 san storage serial number using smu if running smu v3, the msa array chassis serial number is accessed as. The limit in terms of gbyte is 768 tbyte raw, and the supported operative systems are vmware vsphere 5.
The msa array chassis serial number may be accessed through the hpe storage management utility smu, a webbased interface for configuring, monitoring, and managing the. Hpe msa 2040 san storage connecting to the controller. Solution of database, application and web server problems. Default ip range for hp san storage msa 2040 is 10. I am trying to verify connection by just ping host port ip on msa. Its all about vmware, cloud, citrix and data center technologies. Hpe msa 2040, a highperformance storage array designed for entrylevel hewlett packard enterprise users desiring 8gb16gb fibre channel fc, 1 gbe10 gbe iscsi, or 12gb sas connectivity with 4 host ports per controller. Msa 2040 san controller will support up to four connections with options of 16gb, 8gb fc and 10 gbe, 1 gbe iscsi per controller.
We want to set it up in failover so if a1 is not responsive it must switch to b1. The hpmsafcdriver and hpmsaiscsidriver cinder drivers allow hp msa 2040 or 1040 arrays to be used for block storage in. Technical white paper hp msa 2040 storage configuration and best practices for vmware vsphere figure 1. Nov 18, 2014 hp released today an update for its msa storage line. View and download hp p2000 reference manual online. The hp msa 2040 storage array all hp msa storage models offer a common set of features. It uses a single dag to support 750 mailboxes, each. This update will add several virtualization features into the entrylevel storage.
On one server we use port a1 and b1 and on the other server a2 and b2. Run multiple operating systems on a single pc or mac. To upgrade the storage hp msa 2040 firmware when the web management console is not accessible, the use of ftp protocol can solve the problem. Zoning used to be really important for security and keep hosts from seeing the wrong disks and potentially corrupting them, but. My skills include storage, backup, disaster recovery, network and firewall. Msa equipped with hpe msa 10gb sr iscsi sfp 4pk xcvr dell server nic is dell. How to connecting to fibre channel storage youtube. Nov, 2014 i have an msa2040 with 2 sas controllers, and i have two esx hosts plugged in with a 2 port sas hba, one connection per controller. Or skip dedicated san appliances completely and implement storevirtual vsa technology. Hpe msa storage configuration and best practices for vmware vsphere. Jun 04, 2014 hi, im planning to byu hp msa 2040 storage and connect it to 2xxenserver 6. The hpe msa 2040 storage is the ideal solution for customers running oracle, microsoft, sap environments and those customers who are deploying virtual server technologies like vmware and. How to start a simple web server on mac osx copy and paste in vsphere.
Hp msa 2040 site recovery adapter sra the msa 2040 sra, a freetouse plugin, is the program that integrates the vmware vcenter srm with hp msa 2040 arrays. Hpe reference architecture for microsoft sharepoint server. Hi, im planning to byu hp msa 2040 storage and connect it to 2xxenserver 6. As always, it was a breeze contacting hpe support to get the drive replaced since my unit has a 4 hour response warranty. Start out with low cost sas or iscsi connections then swap to fibre channel down the road. A software iscsi adapter is a vmware code built into the vmkernel. What are the steps needed to set the ip addresses for the msa 2040 iscsi ports.
In most cases, your entitlement product serial number is the msa array chassis serial number. This white paper describes a project developed by hewlett packard enterprise in april 2016. I would like to plug my physical vcenter server that has veeam installed on it, directly into the msa2040 as well with a 2 port sas hba. Find answers to msa activeactive in vmware datastore not mounting from the expert. I theorytize now but, if msa 2040 is directly connected to vmware esxi hosts via emulex 10g cna card, it may in fact see only iscsi storage because there is no medium fcoe switch that may separate the. A quick howto to configure a fully redundant infrastructure for using an iscsi storage in a small vmware vsphere environment. By installing fc cards in the nas in target mode, you can use the nas as a san storage device. I added a readcache ssd disk to pool a on my msa 2040.
If the running firmware version is previous to gl210xxxx, the smart component will block the upgrade with a message. You can bind the software iscsi initiator on the esxi host to a single or multiple vmkernel. Realtime application delivery software with lifecycle management. Entry storage for performance hungry apps no matter the demand, now and in the future, there is an hpe msa san storage solution for your needs. It looks to be supported for all the other os options why not vsphere.
You can find more information about vmsc eol in this kb article vmsc solution listing under pvsp can be found on our partner verified and supported products listing. How to find serial number of a hpe msa 2040 san storage. Attaching a windows 2016 host to a storage center array with fiber channel io cards duration. Msa doesnt support direct connect to vmware via iscsi. Click here to view the information on list of available documents for hpe msa 2040 san storage. Dec 12, 20 a quick howto to configure a fully redundant infrastructure for using an iscsi storage in a small vmware vsphere environment. Hp msa refers to msa 1040 and msa 2040 arrays in this article. However, with this being my first drive swap i came across something worth mentioning. Zoning used to be really important for security and keep hosts from seeing the wrong disks and potentially corrupting them, but since pretty much every array these days has lun masking and only shows luns to hosts who need to see them, whats the point of doing single initiator zoning anymore in a small environment.
I had my first predicted disk failure occur on my hpe msa 2040. I theorytize now but, if msa 2040 is directly connected to vmware esxi hosts via emulex 10g cna card, it may in fact see only iscsi storage because there is no medium fcoe switch that may separate the traffic from emulex 10g cna card for ethernetlan, iscsi and fcoefc, also its most probably 10g iscsi controller msa 2040 array version. Msa 2040 includes a double redundant controller available in two versions, san or sas. Hp released today an update for its msa storage line. Solved adding hosts to msa 2040 data storage spiceworks. Hpe oneview for vmware vcenter supports mixed array environments including msa 2040, 1040, p2000, eva. Hpe msa 2040, a highperformance storage array designed for entrylevel hewlett. Increase productivity by creating shared workflows for workstations in. You can find more information about vmsc eol in this kb article vmsc solution listing under pvsp. The p2000 g3 is vaai capable since firmware version t230. Best practices for configuring networking with software iscsi. Aug 26, 2019 the msa array chassis serial number may be accessed through the hpe storage management utility smu, a webbased interface for configuring, monitoring, and managing the storage system. Hpe msa 2040 san storage connecting to the controller cli port.
Howto configure a small redundant iscsi infrastructure for vmware. Looking for metro storage cluster vmsc solutions listed under pvsp. I decided to add the read cache to improve read perfromance as best practice suggests. May 09, 2015 how to configure hp san storage msa 2040 step by step default ip range for hp san storage msa 2040 is 10. Watch this nugget to learn the basics, iscsi best practices and just how easy it is to get connected. Hardware config is 2 hp dl 360 servers and one hp msa 2040. The outline of this document includes the features and recommended configurations for the hpe msa 2040204220502052 product line. How to configure hp san storage msa 2040 step by step. Entry storage for performance hungry apps no matter the.
By installing this new firmware you will get 6 new functions. Start out with low cost sas or iscsi connections then swap to fibre channel. Hi, a friend of mine is in need of a san but on a very tight budget. Msa 1040 2040 iscsi direct connect with vmware vsphere hi. Just to be clear, i only have one vdisk so in the msa there is only one ownership.
821 1062 491 1326 40 626 201 146 1330 284 1316 180 1523 1405 921 753 683 48 560 1265 1051 186 1004 624 137 1511 1105 899 919 689 1296 953 87 1024 1381 869 306 986 343 65 541 1474 494 104 368